ASTM B16 Specification

This specification establishes the requirements for freecutting brass rod, bar, wire, and shapes of any specified cross section produced from Copper Alloy UNS Nos. C36000 or C36010 suitable for high-speed screw machining applications and moderate thread rolling.Units—Values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.

Chemical Composition

Element Composition, %
Copper Alloy UNS No.
  C36000 C36010
Copper 60.0 - 63.0 60.0 – 63.0
Lead 2.5 - 3.0 3.1 – 3.7
Iron, max 0.35 0.35
Zinc Remainder Remainder

Mechanical Properties, Inch-pound

Temper Designation Standard Name Diameter or Distance Between Parallel Surfaces, in. Tensile Strength, min, ksi Yield Strength at 0.5 % Extension under Load, min, ksi Elongation,A min, %
Rod and Wire
060 soft
anneal
1and l.lnder 48 20 15
over 1 to 2, incl. 44 18 20
over 2 40 15 25
H02 half-hard 12/ and under 57 25 7B
over 'h to 1,incl. 55C 25 10
over 1 to 2, incl. so 20 15
over 2 to 4, incl.,and 45 15 20
over 4 40 15 20
H04 hard 1/10 to 3/is incl. 80 45
over o/i• to 1hincl. 70 35 4
over 1h to :V. incl. 65 30 6
Bar
Standard Name Thickness, in. Width, in.  
060 soft anneal 1 and under 6 and under 44 18 20
over 1 6 and under 40 15 25
H02 half-hard 1/2 and under 1 and under 50 25 10
1/2 and under over 1 to 6, incl. 45 17 15
over 1/2 to 2, incl. 2 and under 45 17 15
over 1/2 to 2,incl. over 2 to 6, incl. 40 15 20
    over 2 over 2 to 4, incl. 40 15 20
Note:

A. In any case, a minimum gage length of 1 in. shall be used.
B. For product furnished in coils the elongation shall be 4 % min.
C. If product is specified for thread rolling applications, the minimum tensile strength shall be 52 ksi.

Mechanical Properties, SI

Temper Designation Standard Name Diameter or Distance Between Parallel Surfaces, in. Tensile Strength, min, ksi Yield Strength at 0.5 % Extension under Load, min, ksi Elongation,A min, %
Rod and Wire
060 soft
anneal
25 and under 330 140 is
over 25 to 50,incl. 305 125 20
over 50 275 105 25
H02 half -hard 12 and under 395 170 78
over 12 to 25,incl. 380c 170 10
over 25 to 50,incl. 345 140 15
over 50 to 100, incl.,and 310 105 20
over 100 275 105 20
H04 hard 1.6 to 4,incl. 550 310
over 4 to 12,incl. 480 240 4
over 12 to 18,incl. 450 205 6
Bar
Standard Name Thickness, in. Width, in.  
060 soft anneal 25 and under 150 and under 305 125 20
over 25 150 and under 275 105 25
H02 half-hard 12 and under 25 and under 345 170 10
12 and under over 25 to 150,incl. 310 115 15
over 12 to 50,incl. 50 and under 310 115 15
over 12 to 50,incl. over 50 to 150,incl. 275 105 20
    over 50 over 50 to 100,incl. 275 105 20
Note:

A. In any case, a minimum gage length of 25 mm shall be used. SI elongation values are based on a gage length of 5.65 times the square root of the area for dimensions greater than 2.5 mm.
B. For product furnished in coils the elongation shall be 4 % min.
C. If product is specified for thread rolling applications, the minimum tensile strength shall be 350 MPa.